中国临床研究英文版:2026,39(10):1536-1541
本文二维码信息
码上扫一扫!
机器人辅助下术中三维与二维透视引导骶髂螺钉置入的比较
(1. 甘肃中医药大学,甘肃 兰州 730000;2. 甘肃省人民医院创伤骨科一病区,甘肃 兰州 730000)
Comparison of intraoperative robot-assisted 3D and 2D fluoroscopy guided sacroiliac screw placement
摘要
本文已被:浏览 234次   下载 224次
Received:April 18, 2026   Published Online:October 23, 2026
中文摘要: 目的  比较“天玑”骨科机器人辅助下,术中在C形臂X线机下三维透视与二维透视两种影像引导模式置入骶髂螺钉的效果。方法  回顾性分析2022年4月至2025年10月甘肃省人民医院创伤骨科收治的47例骨盆后环骨折Tile B型、C型行骶髂螺钉固定术患者的临床资料。根据术中影像引导方式分为二维透视组(25例)和三维透视组(22例)。记录并比较两组患者的手术时间、透视时间、导针调整次数等指标。术后通过CT影像,采用Smith 螺钉置入准确度分级标准评估并比较两组螺钉的置入准确率。结果  两组患者年龄、性别、骨折分型等一般资料差异无统计学意义(P>0.05)。与二维组比较,三维组手术时间和累计透视时间更短[(62.73±10.11)min vs(87.36±23.56)min,t=4.754,P<0.01;(99.64±3.68)min vs(115.32±7.58)min,t=3.328,P<0.01],差异有统计学意义;两组导针调整次数比较差异无统计学意义(Z=0.853,P=0.394)。两组S2 螺钉均准确置入,S1 螺钉各有1 例置入不准确,合计准确率二维组与三维组比较差异无统计学意义(96.00% vs 95.45%,P=1.000)。所有患者均未发生重要血管神经损伤等严重并发症。结论  在“天玑”骨科机器人辅助下,三维透视引导能显著缩短手术时间与术中透视时间;二维透视与三维透视引导同样可实现骶髂螺钉的安全、准确置入。临床可根据患者情况及设备条件个体化选择。
Abstract:Objective To compare the efficacy of placing sacroiliac screws under the assistance of the“Tianji”orthopedic robot system using two imaging guidance modes:3D fluoroscopy and 2D fluoroscopy with a C-arm X-ray during surgery. Methods A retrospective analysis of the clinical data of 47 patients with Tile B and Tile C posterior pelvic ring fractures who underwent sacroiliac screw fixation at Gansu Provincial People's Hospital from April 2022 to October 2025. Patients were divided into a 2D group(n=25)and a 3D group(n=22)based on intraoperative imaging guidance methods. Key parameters including operative time,fluoroscopy time,and guide wire adjustment frequency were recorded and compared between the two groups. Postoperative CT imaging was used to evaluate and compare the placement accuracy of screws using the Smith screw placement accuracy grading criteria. Results No significant inter-group differences were found in baseline data including age,gender and fracture classification(P>0.05). Compared with the 2D group,the 3D group had shorter surgery time and cumulative fluoroscopy time[(62.73±10.11)min vs(87.36 ± 23.56)min,t=4.754,P<0.01;(99.64 ± 3.68)min vs(115.32 ± 7.58)min,t=3.328,P<0.01],and the differences were statistically significant. No statistically significant difference was observed in the number of guide wire adjustments between the two groups(Z=0.853,P=0.394). Both groups had their S2 screws placed accurately,while there was one case of inaccurate placement for the S1 screws in each group. Overall,the accuracy rates between the 2D and 3D groups showed no significant difference(96.00% vs 95.45%,P=1.000). None of the patients experienced serious complications like major blood vessel or nerve damage. Conclusion With the assistance of the“Tianji”orthopedic robot system,3D fluoroscopy guidance can significantly reduce both surgical duration and intraoperative fluoroscopy time. Both 2D and 3D fluoroscopy guidance also achieve safe and accurate placement of sacroiliac screws. Clinicians can choose based on the patient's situation and available equipment.
文章编号:     中图分类号:R683.3    文献标志码:A
基金项目:甘肃省卫生健康行业科研项目(GSWSKY2025-80)
引用文本:


Scan with WeChat

Scan with WeChat